Emergency Stop
Selection
Description
With this function, the engine will be shut down automatically if the engine temperature gets too high or the oil pressure gets too low.
An emergency stop switch makes it possible to shut down the engine if there is a risk of personal injury.
Suitable for applications such as:
- Timber trucks
- Tankers
- Crane trucks
Function
If the emergency stop switch is activated, the first operator [&] will sense if the EG power take-off is activated. In this case, the engine will be shut down.
The engine will also be shut down if any of the following functions are activated in combination with the EG power take-off:
- Low oil pressure
- High coolant temperature
If the EG power take-off is not connected, the emergency stop will not affect the engine.